Presentation
Sheet steel box with epoxy finish. Small size guaranties easy integration. The back of the box is shaped so that the device can be attached in a corner (90° angle) or flat (180°angle) on a wall.
Connections
- NC anti-tamper loop
- On/Off control (disappearance of 12V)
- Alarm control (disappearance of 12V) Set/unset Reporting
- Report on On/Off display
- Power supply ( 10 to 15 V-DC)
- Smoke-producing cartridge safety control.
safety
- Anti-tamper : This circuit continuously monitors the STOPY anti-tamper system.
- Confirmation circuit : This circuit eliminate false alarm. It can be switched to the « AND/OR » logical function.
- Cartridge supervision : Electronic device used to test the connection and igniter of the smoke-producing cartridges.
- Delay times : The STOPY-H system has a set exit delay of 60 sec. And an adjustable entry delay (0 or 15 sec.)
Caracteristics
- WEIGHT 1,9 kg
- SIZE (mm) H 320 x L140 x P 70/135
- POWER SUPPLY de 10 à 15 V – DC
- CALCULATED CONSUMPTION 6,4 mA
Smoke cartridge
New generation :
Box H110E and Cartridge H90 E
(from 2006) |
Old generation :
Box H110 and Cartridge H90
(Until end of 2005). |
 |
 |
NT series cartridge are very high-technology cartridges that meet requirements for the protection of goods
and persons. Non-toxic NT series cartridges ( see INERIS report n°95084).
One cartridge provides a maximum of 90 m3 of smoke.