Presentation
Steel cabinet with epoxy finish. Classical lines for easy Integration. Location inside cabinet for an optional 12V-2A battery charger.
Display
- Indication of smoke-cartridge activation
- Supervision of smoke-producing cartridges
- System set
- Power supply on
Connections
- NC anti-tamper loop
- Set/unset Reporting
- Power supply (14,5 V - DC).
- Alarm activation (+12V removed)
- Set Reporting on display
- Confirmation sensor : NC information loop, NC anti-tamper loop, power supply
Safety
- Backup power : This power supply provides 72 hours of autonomy in case provides 72 hours of autonomy in case the mains power is shut off.
- Confirmation circuit : This circuit eliminate false alarm. It can be switched to the « AND/OR » logical function.
- Cartridge supervision : Electronic device used to test the connection and igniter of the smoke-producing cartridges.
- Validation of activation : Security device that prohibits activation of the smoke-producing cartridges during working hours.
- Cartridge safety : An electronic and mechanical device makes replacement of the smoke-producing cartridges completely safe.
- Anti-tamper : This circuit continuously monitors the STOPY anti-tamper system.
Caracteristics
- WEIGHT 8,4 kg
- SIZE(mm) H 360 x L420 x P 140
- POWER SUPPLY 14,5 V - DC
- INCORPORETED BATTERY 12 V – 2 A/H
- OUTPUT DELAY (FIXED) 60 s
- INPUT DELAY (ADJUSTABLE) de 0 à 50 s
Replacement cartridges
NT Non-Toxic series cartridges ( see INERIS report n°95084).
Smoke-producing cartridges Volumes from 100m3 to 200m3 that can be adjusted to fit the space to be protected.